6600-53
Terra Part # 6600-53
Request Quote

Want it faster ? Read about FasTrak

Terra Part # 6600-53
39721
Request Quote

Want it faster ? Read about FasTrak

Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Product Details
  • Provides complete protection from static electricity
  • Water, fire, and chemical resistant PVC tiles
  • •  Panels available: Smooth for heavy loads, Perforated for a smooth airflow, Grated for maximum airflow and low vibration
  • Available in twelve different colorways; base colors are white, gray, blue, pink, green-gray, and green
  • Raised pedestals available in aluminum or steel, and range from three different strengths: low, medium, and high
  • Applications: semiconductor production/assembly, electronic production/assembly, labs, cleanrooms, hospital operation rooms, pharmaceutical facilities, explosive manufacturing
  • Ideal in static-control and sterile environments
  • Speak to a Terra representative for different panel styles and colorways
  • Since regulations vary considerably in different locations, Terra assumes no responsibility for meeting local building regulations, including fire and seismic codes.  Check your local planning department to see what regulations apply to your installation.

Electrical Specifications: None

Manuals & Resources

Cleanroom Accessories & Components

  • Top view of the perforated raised flooring panel Perforated Raised Flooring Panel
  • Cleanroom LED Light Panel Cleanroom LED Light Panel
  • Cleanroom control panel with digital differential pressure gauges Cleanroom Control Panel
  • BioSafe frameless and flush mount cleanroom window BioSafe Frameless Single Tempered-Glass Window
  • Powder Coated Automatic Sliding Cleanroom Door
  • Sanuvair S300 and S1000 Air Purification Systems by Sanuvox Sanuvair S300 and S1000 Air Purification Systems by Sanuvox

Features and Benefits

Learn More: BioSafe Selection Guidelines

Negative-Pressure HD Storage Rooms

Ordering Information

A complete BioSafe Modular Cleanroom includes fan/filter units, lights, and Terra's Power Distribution Modules (ordered separately), in addition to the standard cleanroom components (wall panels and ceiling grid) specified by the selected part number. Other options include pass-throughs, air conditioning modules and windows. Call to discuss your application with a Terra Product Specialist, or submit a QuickQuote request.

Declaration of UL Listing

For applications requiring UL-listed products, you may request a declaration of system listing under UL File E472687 at the time of order, which covers all high-voltage Modular Cleanroom electrical components integrated into Power Distribution System. This Declaration of UL listing helps meet municipal and other permitting requirements that may apply, while ensuring the safety and integrity of electrical components.

  • Energy-saving mode saves 25% of fan operating costs by reducing power consumption during off-hours
  • Maintains round-the-clock cleanroom integrity at lower cost
  • Easy to activate via panel-mounted switch (Wireless Cleanroom Control System also available)

Terra cleanrooms are designed to meet a specified ISO cleanliness rating while in use: with operations in progress, process machinery humming, and personnel in motion. So why maintain that level of performance when a production shift ends and personnel leave for the day?

A cleanroom at rest maintains its target ISO cleanliness standard with much less airflow, fewer air changes—and decreased power consumption. Terra’s Night Service Switch activates a separate operation circuit that drops all Fan/Filter Units (FFUs) into low-energy operation mode, shaving 25% of energy costs from your power bill while maintaining uninterrupted cleanroom performance at your specified cleanliness level (see chart below). With Terra's Night Service Switch, operators can save up to 7,000 kilowatt-hours per year based on a cleanroom system utilizing 10 FFUs.

Operation Setting Airflow: cfm (m^3/hr) Air Speed: ft/m (m/s) Run Amps (Watts)
High Speed 808 (1373) 115 (.58) 4.3 (512)
Medium Speed 717 (1218) 102 (0.51) 3.5 (416)
Night Service 654 CFM (1111) 93 ft/min (0.47) 3.3A (393W)
Non-Sterile HD Compounding

Larger cleanrooms can be partitioned into multiple cleanroom space of different ISO classifications. The double-wall panel design allows BioSafe cleanroom walls to function as either interior or exterior walls, offering an equally clean surface on either side. Modular construction allows our engineers to more easily develop a custom solution at a reasonable price. Installation procedures also remain the same, resulting in fewer errors and delays.

For a higher degree of protection against contamination, personnel should enter a critical processing cleanroom through another controlled environment whenever possible. HEPA-filtered “buffer” rooms or hallways reduce particle counts immediately outside the cleanroom, lessening the impact of airflow turbulence caused by doors opening into the cleanroom. These clean corridors can also protect carts filled with work-in-progress as they move between processing rooms, such as when moving from quality assurance to the packaging phase. Gowning rooms often act as an anteroom, providing a space to transition from unclassified to controlled. For more functional transition options, see Terra’s air showers and tunnels, which use high-velocity air streams to remove loose particles from cleanroom garments prior to entry.

Secure Pedestal Heads

Pedestal heads stabilize floor panels within cleanrooms and other critical environments, effectively minimizing any potential shifting or displacement.

Heavy Duty Structure

Pedestals are available in steel or aluminum, both extremely durable with the ability to hold up to 28,000 pounds.

Reinforced Flooring Framework

Stringers work in tandem with pedestal heads to provide structural support and stability, and distributes weight evenly across floor surfaces.
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • BioSafe Windows

    Double-pane, frameless windows mount flush with no external hardware, for smooth easy to clean surface.
  • Cleanroom UV Sterilization

    UV-C sterilization modules can be installed in the ducting of a recirculating air flow configuration to reduce the bio-burden in an aseptic BioSafe cleanroom.
  • Roll-Up Door Pas-Through Chamber

    Roll-Up Door Pass-Throughs with interlocked doors
  • BioSafe Pass-through Chambers

    Pass-through chambers, available for BioSafe Cleanrooms, include interlocked doors that allow contamination-free sample transfer.
  • In-Wall Utilities Plumbing

    BioSafe cleanroom panels allow flush-mount quick-connect fittings for vacuum, nitrogen, compressed air or other utilities.

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.