Shown: No. 6701-97
IonBar mounted beneath Filter/Fan Unit |
Ionizing Bar
- Provides a continuous stream of static-neutralizing ions
to protect sensitive materials against ESD
- Enhances cleanliness by neutralizing charges that attract
and hold particles on wall, tabletops and other surfaces
- Attaches to cleanroom ceiling T-grid without disrupting
the laminar flow in the cleanroom
- Also ideal for flow hoods
- State-of-the-art technology guarantees intrinsically balanced
ionization
- Requires no calibrationautomatically maintains ion
balance of ± 50 volts
The
Ionizing Bar generates a balanced stream of positive and negative
ions to neutralize surface static charges, safeguarding ESD-sensitive
materials.
State-of-the-art technology makes it one of the most reliable
ionizers available. It emits equal numbers of positive and
negative ions and requires no calibration or adjustments.
Steady-state DC ion emission provides effective discharge,
and mounting beneath ceiling filter/fan units ensures even
distribution throughout the area below.
Discharge times directly under the Bar average 28 seconds
(from ± 1,000 volts to 100 volts, measured in a 4-foot
laminar flow hood in accordance with Ionization Standard ANSI
ESO/ESD S3.1-1991 of the ESD Association).
| IonBar |
|
|
Cat.
# |
$/Each |
| 11"L
with 2 emitters |
2005-05A |
Login |
| 22"L
with 4 emitters |
2005-06A |
Login |
| 33"L
with 6 emitters |
2005-16A |
Login |
| 44"L
with 8 emitters |
2005-07A |
Login |
|
|
| Specifications |
| |
Input: |
24 VAC
(order transformer below) |
| |
Power Indicator: |
Red LED |
| |
Ion Emission: |
Steady-state
DC, 104mA current draw (44" model) |
| |
Emitter Points: |
Replaceable
machined titanium, 3-year estimated life (field
replaceable) |
| |
Air flow: |
50 fpm
(.030 m/s) minimum required at bar for proper operation |
| |
Dimensions: |
2.1"H x 1.2"W x 11"L, 22"L,
or 44"L |
|
| |
|
|
|
Transformers
One transformer drives 10 bars
| Replacement
Transformers |
|
|
Cat.
# |
$/Each |
| 110VAC,
50/60Hz |
2005-09A |
Login |
| 220VAC,
50/60Hz |
2005-09A-220 |
Login |
|
|
Retrofit Kit
Allows mounting of IonBar on
2' x 4' Filter/Fan Units with Terra Universal hoods
and cleanrooms.
| Retrofit
Kit |
| Cat.
# |
$/Each |
|
2005-26 |
Login |
|
Replacement Emitters
Easy-to-replace titanium tips pull out and push
into bar. Approximately 3-year service life.
| Replacement
Emitters |
| Cat.
# |
$/Pair |
|
2005-45 |
Login |
|
|
|
Application Specific Configurations
| |
|
| |
For Modular Cleanroom
(installed)
Includes HEPA or ULPA filter/blower, ionizing bar and
24VDC transformer.
| IonGrid
Filter/Fan Unit |
| Fliter
Type |
Input |
2'
x 4' with
8 emitters |
2'
x 3' with
6 emitters |
2'
x 2' with
4 emitters |
| Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
| HEPA |
110VAC,
50/60Hz |
6701-97 |
Login |
6701-95 |
Login |
6701-93 |
Login |
| 220VAC,
50/60Hz |
6701-97-220 |
Login |
6701-95-220 |
Login |
6701-93-220 |
Login |
| ULPA |
110VAC,
50/60Hz |
6701-98 |
Login |
6701-96 |
Login |
6701-94 |
Login |
| 220VAC,
50/60Hz |
6701-98-220 |
Login |
6701-96-220 |
Login |
6701-94-220 |
Login |
|
| |
|
| |
For
Glove Boxes (installed)
Includes ionizing bar and 24VDC power supply along
with one fan per emitter pair mounted to ensure
uniform ion distribution throughout the glove box.
|
| Glove
Box IonBar |
|
|
110VAC,
50/60Hz |
220VAC,
50Hz |
| Cat.
# |
$/Each |
Cat.
# |
$/Each |
| 22"L
with 4 emitters |
2005-30 |
Login |
2005-30-220 |
Login |
| 33"L
with 6 emitters |
2005-32 |
Login |
2005-32-220 |
Login |
| 44"L
with 8 emitters |
2005-31 |
Login |
2005-31-220 |
Login |
|
|
|

Model shown: 2005-30
|
|
|
| |
|
| |
For Laminar
Flow Hoods (installed)
Includes ionizing bar and 24VDC power supply mounted to
filter/blower module of specified laminar flow hood. Overall
hood width should be at least 2" larger than bar
length selected.
| For
Laminar Flow Hoods |
|
|
110VAC,
50/60Hz |
220VAC,
50Hz |
| Cat.
# |
$/Each |
Cat.
# |
$/Each |
| 11"L
with 2 emitters |
2005-35 |
Login |
2005-35-220 |
Login |
| 22"L
with 4 emitters |
2005-36 |
Login |
2005-36-220 |
Login |
| 33"L
with 6 emitters |
2005-38 |
Login |
2005-38-220 |
Login |
| 44"L
with 8 emitters |
2005-37 |
Login |
2005-37-220 |
Login |
|
|