Portable CleanBooth

  • Castered frame positions Filter/Fan Unit (FFU) above benchtop, large process equipment, repair operations anyplace you need a temporary laminar flow of filtered air
  • FFU provides an average air flow speed of 90 feet/minute (measured with HEPA filter)
  • Quiet operation: 50 dBA measured 30" from filter face
  • Flexible side panels create a 3-sided enclosure, enhancing the laminar flow
  • Available with a variety of work surfaces to meet your requirements

Terra's Portable CleanBooth™ provides a mobile, versatile mini-cleanroom wherever you need it! It is ideal for operations with probe stations, screen printers and other free-standing process equipment, as well as benchtop kitting or assembly.

FFU: Quiet, Reliable Operation


It consists of two modules: a filter/fan unit (FFU), which houses a particle filter, and a mobile support frame. The 24" x 48" x 12.25" FFU houses a HEPA filter, rated 99.99% efficient with 0.3 micron particles. Its compact, lightweight design makes it ideal for mounting either to the mobile frame or to any standard 2' x 4' ceiling grid. Its internal baffle system ensures uniform face velocity, and its 50 dBA noise rating is the best in the industry.

Mobile Frame Support


The FFU is attached to a castered support frame for easy positioning at locations throughout your facility.

Fabricated of 1" x 2" square steel members, it positions the filter face 70" above the floor (38" above the standard work benches offered below). The nonmarking castered wheels lock in place to keep the station where you need it. Its sturdy construction safely supports the FFU with minimal vibration. And because the frame does not come in contact with the bench top or equipment it services, this blower vibration is effectively isolated from the work in progress.

Flexible Side Panels Restrict Air Flow to Optimize Cleanliness
For enhanced laminar flows, select the optional side panels, available in three materials:

Cleanroom-Grade Vinyl is fire retardant and low outgassing.

Static-Dissipative Vinyl is manufactured with permanent built-in static inhibitors that, unlike topical treatments, will not wear off.

Non-outgassing Polyurethane is made from inherently static-dissipative polyurethane that provides permanent, humidity-independent ESD protection for sensitive manufacturing conditions. Polysim contains no plasticizer, making it virtually non-outgassing.

Side softwall panels attach to the FFU by means of a unique, noncontaminating Grip-Track mounting system that eliminates cracks and seams where germs or particles can collect.


Mobile Frame Support
Includes set of 4 casters, 2 with locking brakes. Order Filter/Fan Units separately.
Dimensions
(W x D,
nominal)
No. of FFUs
(order below)
Fixed Height
Cat.# $/Each
53" x 30" (1) 24" x 48" 1870-01 Login
76" x 30" (2) 24" x 36" 1870-02 Login

Side Softwall Panel Kits
Includes curtains of specified material that attach to the FFU. Kit catalog number includes installation of Grip-Track mount on two sides and rear of FFU. Panel length: 60". Panels can be cut to bench level.
For Cleanbooth Cleanroom Vinyl Anti-Static Vinyl Polyurethane
Cat.# $/Each Cat.# $/Each Cat.# $/Each
49" width 1330-00A Login 1330-01A Login 1330-02 Login
77" width 1330-05A Login 1330-06A Login 1330-07 Login

Filter/Fan Unit (FFU)
Includes HEPA filter rated 99.99% efficient @ 0.3µm particles. Avg. flow @ 90 FPM: 650 CFM. See ordering chart for required quantity.
Dimensions
(nominal)
24" x 48" 24" x 36"
Cat.# $/Each Cat.# $/Each
110VAC, 60 Hz 6701-99A Login 6702-08A Login
220VAC, 50/60Hz 6701-99A-220 Login 6702-08A-220 Login

Filter/Fan Unit (FFU) with IonBar™ Static Neutralizer
These FFUs incorporate low-wattage ionizers that emit balanced streams of static-neutralizing ions to enhance ESD and particle control.
Dimensions
(nominal)
24" x 48" 24" x 36"
Cat.# $/Each Cat.# $/Each
110VAC, 60 Hz
6701-97 Login 6701-95 Login
220VAC, 50/60Hz 6701-97-220 Login 6701-95-220 Login

Fluorescent Light
Dimensions
(nominal)
115/227VAC, 50/60Hz
Cat.# $/Each
35.5" long (1)
1870-10 Login
47" long (2) 1870-11 Login
(1) Two required for 73"=wide Cleanbooth. Includes Installation
(2) One required for 49"=wide Cleanbooth. Includes Installation

Work Benches
These benches provide a work surface 32" above the floor. Several surface materials are available to meet specific applications. The epoxy-finished steel frame includes a stainless steel scuff guard on the lower leg member to prevent scratching and chipping. The "C" base features recessed legs for operator comfort and convenience.

Work Benches (A-base design)
Bench Top
Dimensions
W" x D"
Nonconductive
Laminate
Conductive
Laminate
Polypropylene
With Raised Lip
304 Stainless Steel-
Solid
304 Stainless Steel-
Perforated
Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each
48 x 23 1722-00 Login 1728-00 Login 1522-00 Login 1521-45 Login 1522-56 Login
72 x 30 1726-00 Login 1732-00 Login 1522-02 Login 1752-00 Login 1522-58 Login
 
Preferred Client
Services Include:
QuickStart Manuals
Price Checker
Update Profile
You are not logged in.
Type email address and click Login.
Request a Quote
The QuickQuote planning form makes it easy to specify the system for your requirements
Product Selection


Hoods
Section Resources
Laminar Flow Stations
Vertical Laminar Flow Stations
Horizontal Laminar Flow Stations
Portable CleanBooth
Wall-Mount Hood
Narrow Profile Hood
Temperature Stability Chamber
Laminar Flow Benchtop Hoods
Laboratory Fume Hoods
Ductless Fume Hoods & Benches
Biological Safety Cabinets
Hood Accessories


All prices and specifications are subject to change without notice. Crating charges apply to selected items.
  Terms and Conditions
  Precision Fabrication to Your Specs! Call to discuss your requirements for CNC routing and drilling.
  Top of page
Did You Know  
finishing work
 

Terra performs all finishing work, including powder coating, at its manufacturing facility in Fullerton, CA.

 
     
 
 

Tiny dirt particles can carry bacteria, viruses and other pathogens?

 
HEPA-filtered hoods and workstations will remove bacteria and viruses”
 

Terra's HEPA-filtered hoods and work stations effectively remove these unwanted hitchhikers!