Price Checker Manuals QuickQuotes About Terra Contact Us
Exhaust Fume Filter Systems
Slit Nozzles and acrylic hood
Slit Nozzles Acrylic Hood

Exhaust Fume Filter Systems

  • Versatile exhaust system removes annoying fumes to maintain a healthy workplace!
  • Swing-arm design allows effective placement of exhaust pick-up tools
  • Modular design lets you select the items required for your application
  • Powerful Exhaust Filter/Fan Module removes most organic fumes to allow safe indoor release (see following page)

This versatile system removes smoke and fumes from soldering, epoxies, solvents or other sources.

It is ideal for highly localized operations, for which an exhaust fume hood may be too constrictive or cumbersome. The easy-position swing arm lets you position the pick-up tool exactly where you need it yet won't interfere with soldering or other operations.

The exhaust arm can be mounted to either a benchtop or wall. A complete system includes the following modules (select each separately, using the diameter to suit your requirements): an Exhaust Filter/Fan Module, an exhaust arm (2" or 3" diameter), and corresponding mounting bracket, connection hose, and pick-up tools.

In choosing the exhaust arm, keep in mind that the smaller, 2"-diameter arm may, under full blower force, create a sucking sound, which reminds an operator of the vacuum force but which may be distracting. The larger, 3" arm requires an adapter for use with the 2" connecting hose.

Module 2"-diameter
Cat. # $/Each
Exhaust Arm-Anti-Static 9001-02 Login
Table Mounting Bracket 9001-41 Login
Wall Mounting Bracket 9001-05 Login

Adapter
(Connects 2" hose to 3" exhaust arm)

9001-14 Login
Pick-Up Tools    

Slit Nozzle, 8"W, Anti-Static

9001-38 Login

Slit Nozzle, 8"W

9001-10 Login

Pipe Nozzle, 4"L

9001-12 Login

Pipe Nozzle, 4"W, Anti-Static

9001-39 Login

Acrylic Hood, 14"W

9001-15 Login

Funnel Nozzle, 8" Dia.

9001-42 Login

Funnel Nozzle, 8" Dia. with Halogen Light

9001-17 Login
* Hoses include one set of clamps. Select the adapter to use 2"-diameter hose
with 3"-diameter exhaust arm.

Filter/Fan Module

Filter/Fan Module

Designed for remote exhaust ventilation applications, the module incorporates a 125-CFM continuous-duty, brushless blower designed for quiet operation and automatic thermal protection.

It accommodates an activated charcoal exhaust purification filter to allow safe release of exhaust fumes (see page 424 for full specifications on exhaust filters). This filter is now bonded and encapsulated in a sleeve that functions as a prefilter negating the need for a separate prefilter.

In addition, a HEPA or ULPA final filter may be specified for exhaust release into a cleanroom. This module comes with a standard 8"-diameter stainless steel flange for connection to exhaust hosing. Select either a 2"- or 3"-diameter flange for use with hosing from the Exhaust Fume Filter System. Housing Dimension: 14"W x 13.5"D x 32.25"H

Cat. # $/Each
Filter/Fan Module
120 VAC, 50/60Hz 9001-18A Login
220 VAC, 50Hz 9001-18A-220 Login

Exhaust Flanges (stainless steel)

2" diameter 9001-19A Login
3" diameter 9001-40 Login
Activated Charcoal Filter 1716-00A Login
HEPA Final Filter
Rated 99.99% efficient @ 0.3µm
1681-02 Login
ULPA Final Filter
Rated 99.999% efficient @ 0.12µm
1681-10 Login
static pressure and air flow graph


Spiralock™ Zephyr-D Vacuum Hose
Spiralock Zephyr-D Vacuum Hose
 

Spiralock™ Zephyr-D Vacuum Hose

  • Crush-proof and built to last and last
  • Ideal for use in Terra’s Exhaust Fume Filter System
  • Easily and quickly installed by anyone

Easily cut or coupled on the job Terra's Spiralock™ Zephyr-D Vacuum Hose is ideal for moving air, gases, dust, fumes or liquid by suction, gravity or pressure. It will give you high-quality performance at a reasonable price. It features a smooth interior and excellent flexibility in a crush-proof construction made to withstand rugged daily use. The non-wire interlocking construction allows it to be crushed, kinked, jumped on, twisted, or run over by a truck—it will come right back to shape. There is no metal used in the construction and therefore none to corrode. Use it with dry or wet-dry vacuums.

This hose will handle a great many chemicals (information on chemical resistance is available from Terra). It is not, however, meant to be used with any petroleum-based products such as gasoline, kerosene, oil and solvents. A wide range of temperature uses from -50°F to +150°F are acceptable.

Ordering Information: Specify desired length as quantity
(e.g., quantity (6) = 6-ft length)
Cat. # $/Foot
2", Gray 9001-23 Login
Cat. # $/Each
2" Vinyl Cuff 9001-24 Login
 
Preferred Client
Services Include:
QuickStart Manuals
Price Checker
Update Profile
You are not logged in.
Type email address and click Login.
Request a Quote
The QuickQuote planning form makes it easy to specify the system for your requirements
Product Selection


Hoods
Section Resources
Laminar Flow Stations
Laminar Flow Benchtop Hoods
Laboratory Fume Hoods
Ductless Exhaust Fume Stations
  Protector XVS Ventilation Stations from Labconco
FilterMate Portable Exhausters from Labconco
Paramount Filtered Enclosures from Labconco
Exhaust Fume Hoods
Ductless Exhaust Fume Hood
Environmental Control Modules
Universal Hoods
High-Clearance Chemical Fume Hoods
Ductless Work Station
DownDraft Work Station
Exhaust Fume Filter System
Biological Safety Cabinets
Hood Accessories


All prices and specifications are subject to change without notice. Crating charges apply to selected items.
  Terms and Conditions
  Precision Fabrication to Your Specs! Call to discuss your requirements for CNC routing and drilling.
  Top of page