| Options Check List for Stainless Steel Chambers |
|
 |
Tilt-Up Viewing Window
Swings open for easy access. Dual piston mechanisms hold the window securely open. Price includes modification of Series 300 or 400 stainless steel glove box to include hinged viewing window. Must be ordered together with affected glove box. Dimensions given are for cut-out. Viewing Window has a 304 stainless steel frame.
 |
Cat. # |
$/Each |
For single chamber
(28.25"W x 12.75"H) |
1684-92 |
Login |
For twin chamber
(52.625"W x 12.75"H) |
1684-93 |
Login |
|
|
 |
Iris Ports
Self-closing silicone ports allow convenient access to glove boxes without the need for special gloves; the iris opens when you insert hands and closes when you remove them. Easy to install onto standard glove portssimply slip them into the port from the inside of the glove box.
| Cat.
# |
$/Each |
|
1694-54 |
Login |
|
|
 |
Disposal Trap Door
Hinged door can be installed on any stainless steel glove box to allow easy disposal of waste or introduction/removal or small parts. Chrome-plated latch is easy to engage and forms an airtight seal. Standard location is next to air lock. Dimensions: 8" x 12"
| Cat. # |
$/Each |
|
1694-41 |
Login |
|
|
 |
Sloping Bottom with Drainage Valve
Ideal for solvent cleaning and other chemical processing. A platform (either perforated stainless steel or wire grid) provides a level work surface. Chemical spills drain to a reservoir with a convenient drain valve (specify stainless steel, PTFE, polypropylene, or other valve material).
| Cat. # |
$/Each |
|
1694-42 |
call TUI |
|
|
 |
Detachable Bottom
Removable bottom panel allows Series 500 glove box to be lifted for easy placement over large equipment. Attaches and seals by means of two clamps.
  |
Cat. # |
$/Each |
| 48"W Box |
1702-50 |
Login
|
| 96"W Box |
1702-51 |
Login
|
|
|
 |
Bellows Eyepiece Interface
This cutout is sealed with a bellow-type diaphragm to allow viewing of a stereo microscope positioned inside any of Terra' s stainless steel glove boxes. Standard cutout size is 8"W x 6"H. Specify desired location or custom size when ordering.
| Cat. # |
$/Each |
|
1681-53 |
Login |
|
|
 |
Glove Box Dual Purge System
Provides variable-flow purge control to save nitrogen expenses.
 |
Cat. # |
$/Each |
| NitroWatch Controller |
9500-00A |
Login |
| NitroWatch Sensor |
9500-02A |
Login |
| Works in tandem with the Dual Purge System to maintain the selected relative humidity level. |
Works in tandem with the Dual Purge System
to maintain the selected relative humidity level. |
|
 |
Stainless Steel Automatic RB® (Relief/Bleed) Valve
Safeguards glove box against overpressures. Required for operation with Dual Purge System.
| Cat. # |
$/Each |
|
1606-60 |
Login |
|
|
 |
Exhaust
Filter Modules
These modules allow safe ductless release of air inside an isolation
chamber.
HEPA
Filter Module
99.99%
efficient at removing particles as small as 0.5µm in diameter,
including most pathogens and aerosols.
| Cat.
# |
$/Each |
|
1684-84 |
Login |
|
Activated
Charcoal Module
Removes
most organic vapors, including animal odors.
| Cat.
# |
$/Each |
|
1110-33 |
Login |
|
HEPA/Charcoal
Module
Includes
activated charcoal filter above, plus a downstream final HEPA
filter.
| Cat.
# |
$/Each |
|
1110-34 |
Login |
|
|
|
|
 |
Gas Mixer
Allows precise mixtures of process gases, such as He/N2 or He/Ar used in package seam welding.
| Cat. # |
$/Each |
|
2701-00 |
Login |
|
|
 |
Trace
Oxygen Analyzer
Detects concentration as low as 1 ppm(v).
| Cat.
# |
$/Each |
|
2005-97 |
Login |
|
|
 |
Dryex Gas Dryer
Removes moisture and particulates from compressed air feed.
| Cat. # |
$/Each |
|
9082-00 |
Login |
|
|
 |
Nitrogen Generator
Semiporous micromembrane technology yields 99.9% pure nitrogen to ensure an economical, reliable, uninterrupted gas source.
| Cat. # |
$/Each |
|
2700-09A |
Login |
|
|
 |
Humex Humidifier
Humidifies glove box from ambient to 100% RH.
| Cat. # |
$/Each |
|
9081-00 |
Login |
|
|
 |
Process Gas Heater
Heats process gas up to 350°F for high-temperature testing.
| Cat. # |
$/Each |
|
4320-00 |
Login |
|
|
 |
Process Gas Cooler
An economical way to cool process gas 20°F below ambient, down to 40°F.
| Cat. # |
$/Each |
|
9450-00 |
Login |
|
|
 |
Constant Temperature Control System
This constant temperature control system features heater and refrigeration modules working together to maintain a specific temperature in a glove box. Complete information.
Temperature
Range |
Compressor Size |
BTU/Hour
Capacity |
110 VAC, 50/60Hz |
220 VAC, 50/60Hz
|
| Cat. # |
$/Each |
Cat. # |
$/Each |
-10º to 120ºF |
0.5HP |
3800 |
1694-76 |
Login |
1694-76-220 |
Login |
-25º to 120ºF |
0.75HP |
5900 |
1694-78 |
Login |
1694-78-220 |
Login |
5º to 120ºF |
0.5HP |
3800 |
1694-75 |
Login |
1694-75-220 |
Login |
5º to 120ºF |
0.75HP |
5900 |
1694-77 |
Login |
1694-77-220 |
Login |
|
|
 |
Ionizing Blower
Provides safe, effective static neutralization inside a glove box or similar enclosure. Designed for overhead chamber mounting, it generates a balanced stream of positive and negative ions to neutralize surface static charges, safeguarding ESD-sensitive materials. Includes fans for even distribution.
| Glove Box IonBar (installed) |
|
110VAC, 50/60Hz |
220VAC, 50Hz |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 22"L with 4 emitters |
2005-30 |
Login |
2005-30-220 |
Login |
| 33"L with 6 emitters |
2005-32 |
Login |
2005-32-220 |
Login |
| 44"L with 8 emitters |
2005-31 |
Login |
2005-31-220 |
Login |
|
|
 |
Ionization Module
Provide safe, reliable static neutralization for any glove box enclosure.
click here |
|
 |
Vacuum Control Module
Controls vacuum pump operation to maintain desired vacuum level inside the Series 400 vacuum antechamber or pass-through oven.
| Cat. # |
$/Each |
|
1681-75 |
Login |
|
|
 |
Magnehelic Gauges
This MAGNEHELIC® Principle is a method of transmitting the effects of changes in air pressure from a diaphragm to an indicating pointerby means of magnetic linkage and without the use of gears or other direct mechanical linkages. This system avoids wear and physical contact, which might destroy the accuracy and sensitivity of the instrument. It delivers accuracy to within 2% of full scale. Complete information.
| MAGNEHELIC® Gauges |
Pressure Range
(inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 0-0.5 |
1 lb. 2 ozs. |
2625-08 |
Login |
2625-30 |
Login |
| 0-1.0 |
1 lb. 2 ozs. |
2625-09 |
Login |
2625-31 |
Login |
| 0-2.0 |
1 lb. 2 ozs. |
2625-10 |
Login |
2625-32 |
Login |
| 0-3.0 |
1 lb. 2 ozs. |
2625-11 |
Login |
2625-33 |
Login |
| 0-4.0 |
1 lb. 2 ozs. |
2625-12 |
Login |
2625-34 |
Login |
| .25-0-.25 |
1 lb. 2 ozs. |
— |
— |
6600-87 |
Login |
|
|
 |
PHOTOHELIC® Pressure Control
PHOTOHELIC® models combine the MAGNEHELIC® gauge with a precise pressure switch that lets you control low and high gas pressures. Knob controls adjust dual set points, which allow for variable deadband control. These set points contain photocells that actuate DPDT relays when room pressures reach a preset upper or lower limit, and they can be set up to control corrective damper action. As the room pressure changes in response to damper motion, and the indicator returns to the null band, damper motion is halted. Complete information.
| PHOTOHELIC® Gauges |
Pressure Range
(inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 0-0.5 |
4 lbs. |
2625-13 |
Login |
2625-35 |
Login |
| 0-1.0 |
4 lbs. |
2625-14 |
Login |
2625-36 |
Login |
| 0-2.0 |
4 lbs. |
2625-15 |
Login |
2625-37 |
Login |
| 0-3.0 |
4 lbs. |
2625-16 |
Login |
2625-38 |
Login |
| 0-4.0 |
4 lbs. |
2625-17 |
Login |
2625-39 |
Login |
| .25-0-.25 |
4 lbs. |
— |
— |
6600-86 |
Login |
|
|
 |
Minihelic II® Differential Pressure Gauges
Combining clean design, small size and low cost with enough accuracy for all but the most demanding applications our Minihelic®II gauge offers the latest in design features for a dial type differential pressure gauge. Complete information.
| Minihelic II ® Gauges |
Pressure Range
(inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 0-0.5 |
6 ozs. |
2625-43 |
Login |
2625-48 |
Login |
| 0-1.0 |
6 ozs. |
2625-44 |
Login |
2625-49 |
Login |
| 0-2.0 |
6 ozs. |
2625-45 |
Login |
2625-50 |
Login |
| 0-3.0 |
6 ozs. |
2625-46 |
Login |
2625-51 |
Login |
| 0-5.0 |
6 ozs. |
2625-47 |
Login |
2625-52 |
Login |
|
|
 |
DIGIHELIC® Differential Pressure Controller
Allows the selection of pressure, velocity or volumetric flow operation. Two SPDT control relays with adjustable dead bands are provided, with scalable 4-20mA process output. Complete information.
| DIGIHELIC® Differential Pressure Gauge |
Pressure Range
(inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each** |
Cat. # |
$/Each** |
| 0 – 1.0 |
14 lbs. |
2625-26 |
Login |
2625-40 |
Login |
| 0 – 5.0 |
14 lbs. |
2625-27 |
Login |
2625-41 |
Login |
| 1.0 – 0 – 1.0* |
14 lbs. |
2625-28 |
Login |
2625-42 |
Login |
*Bi-Direction Range. Velocity and volumetric flow not available on bi-directional unit.
**Price includes installation |
|
| |
4-Outlet Power Strip
Includes master on/off switch and resettable
15-amp circuit breaker. Installed along rear wall of glovebox.
| 4-Outlet Power Strip |
 |
Cat. # |
$/Each |
| 120VAC, 50/60 Hz |
1681-80 |
Login |
|
| |
|