GBX_TER200SS
Stainless steel door frames with unique "e" profile elastomer gasket increase structural rigidity, extend service life, improve sealing performance.
Specifications
Construction: Solvent-welded .5 "-thick clear acrylic or polycarbonate; chrome-plated hardware
Door
Openings:
10" x 10" gasketed (accommodates either vacuum interchange chamber or standard Terra Air Lock); gasketed front access door optional (for introduction of large objects)
Arm Ports: 9" round with flange for connecting glove assembly/port caps
Vacuum Control: 0-30" vacuum gauge provided with dual shutoff valves and barbed-hose fittings. Flange with outlet port provided with selection of remote filter/blower module.
Note: The vacuum safety valves provided with each Series 200 Negative Pressure Glove Box and Negative Pressure Air Lock are essential to safe operation of this system, especially when operated with a vacuum pump. Removal of these valves could result in damage to your equipment!
Note: Vacuum gauge and shutoff valves are standard with all applications that include vacuum service. For applications with a filter/fan unit, this hardware is not included. See following pages for more information.
 

Negative Pressure Glove Boxes (Series 200)

  • Ideal for drying, degassing, and ventilation applications
  • Clear construction (of acrylic or polycarbonate) provides full visibility of work in progress
  • Sturdy construction allows sustained negative pressure operation at 5" WG (29.9"Hg in vacuum antechamber)
  • Solvent welding and chrome-plated hardware ensure a completely noncontaminating environment
  • Optional remote filter/blower module provides safe exhaust fume venting or purification
  • Select cylindrical vacuum chamber for higher vacuum levels
  • 9" round arm ports accommodate port caps and sleeve/glove combinations
  • Vacuum safety valve included to prevent damage to walls or seal

These economical vacuum glove boxes are designed for degassing operations, chemical mixing, biological tests, and other processes requiring sustained negative pressure.

Clean, Sturdy, Versatile
Each chamber is fabricated out of solvent-welded .5" transparent material that combines full visibility with light weight, cleanliness and durability. Dual glove ports allow full access to work in progress. Select acrylic for general applications, or polycarbonate for resistance to a wide range of chemicals and thermal stress.

Equipped with a vacuum safety valve on a standard basis, these chambers are designed for operations with sustained negative pressures down to 5" WG (Water Gauge). All hardware, including latches and hinges, is chrome-plated, and solvent welding ensures a strong, seamless, air-tight structure that won't leak or outgas.

Improved Access Doors Reduce Wear, Enhance Performance
Dual side access doors open inward to allow easy parts transfer from inside the chamber. Doors feature stainless steel reinforcement frames that increase the structural rigidity of the door by a factor of five. A built-in LiftLatch securely seals the door without applying lateral torque that could damage hinges.

All doors include unique, one-piece "e"-profile elastomer gaskets that will not compress or migrate over time. Their superb sealing capability saves nitrogen, eliminates maintenance, and extends the service life of access doors—typically the only component of a glove box that shows wear.

Versatile Configurations Support Many Negative Pressure Applications
These glove boxes are designed for applications requiring low-level negative pressures, continuous high-volume ventilation, or sustained vacuum at one atmosphere. See following pages for more information on each configuration outlined below.

By attaching a vacuum pump and vacuum controller, you can dry or degas components at up to 5" WG of negative pressure in either the main chamber or negative pressure air lock. In this application, dual vacuum shut-off valves allow connection to the pump and vacuum bleeding. A safety pressure valve ensures that internal pressure does not exceed 5"WG.

For degassing at one atmosphere (29.9" Hg), select the vacuum antechamber. The pass-through design of this antechamber lets you introduce parts measuring up to 10" x 10" into the glove box for packaging or other processing following vacuum cycling.

Two configurations are available for continuous ventilation of the glove box during soldering, chemical mixing, or other operations that generate noxious fumes. A remote filter/blower module can be connected to the glove box via a 6" flange. Fumes are drawn through the conduit for remote exhausting or vapor removal. Make-up air enters the chamber either through iris glove ports or a HEPA-filtered intake port on top of the box. As an alternative to remote ventilation, a filter/fan unit can be installed directly on top of the glove box. Its ventilation fan draws fumes through a charcoal filter for purification or into an exhaust conduit for remote exhausting. Make-up air enters the chamber through iris glove ports.

Two .5 "-thick plexiglass port caps are included with each Negative Pressure Glove Box to allow the 8" round arm ports to be sealed. These caps are recommended during processes with negative pressure in order to relieve strain on gloves and glove clamps (gloves must be ordered separately).

 
How to Order:
  1. Select the glove box of the desired material (either plexiglass or polycarbonate). Models are available with or without the swing-up front access panel. Note: Terra recommends selection of a stainless steel work surface to prevent scratching in all plastic chambers.
  2. Read across the ordering table to select a vacuum antechamber or air lock (price includes standard right-side installation). Refer to description on following page for more information on these options.
  3. Select other accessories below.
Cat. # $/Each
Operating Manual 1800-42 Login
Wafer/Custom design
Series 200 Dim. Illust. 50% V2

Glove
Ports
A D F H I M N
2 16.25 24 35 22.125 11.5 10 11

Available in Static-Dissipative PVC for long-lasting ESD & particle control.
Sheets in stock for immediate delivery.

 

Series 200 Negative-Pressure Glove Boxes
With Front Access Panel Without Front Access Panel
Acrylic* Polycarbonate Acrylic* Polycarbonate
Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each
1681-13B Login 1681-14B Login 1681-15B Login 1681-16B
*Acrylic is damaged by alcohol and other cleaning agents.

Corresponding Accessories

Vacuum
Antechamber
(12" Diameter)

Negative Pressure
Air Lock
Standard
Air Lock
Replacement Port Covers
12"L 23"L External Mount
Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each
1681-63 1681-67 1680-93B 1680-78B 1694-53
Other Optional Accessories
  GloveBox

Swing-Up Front Access Panel
Allows convenient introduction of large parts into the processing chamber. Cut-out size: 20"W x 10"H (other sizes available; specify when ordering). See ordering information above.

 

Air Locks
Negative pressure air locks (shown above) include a 0 - 30" Hg vacuum gauge, dual vacuum shutoff valves, and a pressure safety switch (set at 5"WG). Dimensions: 11.5" x 10" x 10". Stainless steel door frames ensure durable, rigid structure that won't crack or warp. Standard mounting is on the right side of the glove box. See ordering information above.

  168906 Changeable Sleeve and Glove Combination
These accordion sleeves fit into the ports of Terra's atmospheric chambers for safe, easy handling of materials. They can be used with a variety of gloves, allowing you to change glove size or type without changing the sleeve itself. Supplied with one pair of nitrile industrial gloves (select desired size). Clamps included.

Changeable Sleeve and Glove Combination

Glove
Size
With 18" Sleeve
Cat. # $/Each
8 1689-46 Login
9 1689-47 Login
10 1689-48 Login
    Stainless Steel Work Surface
Protects the bottom of the chamber against scratching. Price includes installation.
Cat. # $/Each
1680-69 Login
Negative-Pressure Applications:
 
GBX_TER200SS
GBX_OrdIllus05
Series 200 Glove Box with Vacuum Service to 5" WG
This application, which supports sustained negative pressure to 5" WG in either the main chamber or the air lock, is ideal for degassing or applications with fuming chemistries.

The Series 200 Glove Box includes dual shutoff valves (for vacuum line and backfill), vacuum gauge and pressure safety switch. Port caps, included with the box on a standard basis, allow the operator to seal the box during negative pressure processing. After bleeding the vacuum, the operator can remove these ports to allow access to the chamber.

A Low-Vacuum Control Module ensures safe, efficient pump operation. The Solenoid vacuum kit includes all vacuum connections required for turnkey operation.

Negative-Pressure Air Lock See above.

Low-Vacuum Control Module
Includes a vacuum gauge with set point control, on/off switches for pump and vacuum solenoid.
Cat. # $/Each
1685-99 Login
1685-99-220 Login
 

Low-Vacuum Solenoid Connection Kit
Includes solenoid valve and fittings necessary for connection of vacuum pump to Vacuum Control Module at left. Order Low-Vacuum Vacuum Controller separately.
Cat. # $/Each
5400-30 Login

 
Diaphram Vacuum Pump
Performs reliable, economical vacuum pumping for low-vacuum applications.
With metering kit Without metering kit
Cat. #
$/Each
Cat. #
$/Each
120VAC, 60Hz 7903-00 Login 7902-00
220VAC, 50Hz 7903-01 Login 7902-01
Exhaust Fume Applications:
 
Filter/Blower Module
Provides Remote Ventilation
Series 200 Glove Box with Remote Ventilation
In this configuration, noxious fumes generated inside the Series 200 Glove Box are ducted through a 6"-diameter conduit to a remote filter/blower module.

A variety of filters are available to help you meet OSHA and other environmental requirements for exhaust purification. The activated charcoal filter listed below removes most organic chemical vapors to allow safe indoor release. Specialized filters are available for other fumes. HEPA or ULPA particle filters can be used to remove particles as small as 0.12µm

For particle-sensitive applications, an ULPA-filtered Air Inlet Module is mounted on top of the Series 200 chamber. In this application, an operator uses gloves to access materials inside the chamber.If particles are not a concern, specify iris ports. These ports, made of multi-layered, self-closing silicone panels, allow make-up air to enter the chamber. Note: in this configuration, port caps cannot be used while the ventilation unit is turned on.

Air Inlet Module
Features a 3"-diameter inlet port. An acrylic enclosure houses an ULPA filter, rated 99.999% efficient at removing particles 0.12 microns in diameter.
Cat. # $/Each
Air Inlet Module 1685-81 Login
Replacement ULPA Filter 3333-35 Login
 
Exhaust Flange
This 6"-diameter flange allows connection of conduit to a remote filter/blower module or other ventilation system. Specify other flange diameters.
Cat. # $/Each
Acrylic 1681-85 Login
Polycarbonate 1681-86 Login
 
Remote Filter/Blower Module
Cat. # $/Each
Remote Filter/Blower Module 110V 1681-68A
  220V 1681-68A-220
Activated Charcoal Purification Filter   1716-00A
HEPA Filter   1681-02
ULPA Filter   1681-10
The 14"W x 13.5"D x 32.25"H polypropylene module houses a 740 CFM variable-speed blower that ventilates fumes inside the Series 200 Glove Box. Several filters are available for removal of organic chemical vapors or particles (order separately). All models are 110VAC/60Hz (add "-220" to part number for 220VAC/50Hz).
 
GBX_TERIRISPORTSIris Ports
These self-closing silicone ports allow convenient access to glove box without the need for special gloves. They also allow make-up air to enter the chamber in configurations without an Air Inlet Module.
Cat. # $/Each
1694-54 Login
 
 
Series 200 Glove Box with Filter/Blower Module

Series 200 Glove Box with On-Board Ventilation Module
This configuration includes a Filter/Blower Module that ventilates fumes inside the Series 200 Glove Box.

This module, available in several materials, allows exhaust fumes to be ducted to an in-house exhaust system or purified by an activated charcoal filter for safe release. The versatile filter housing also accommodates a final particle filter (HEPA or ULPA).

Make-up air enters the chamber through iris ports made of multi-layered, self-closing silicone panels. Note: In this configuration, port caps cannot be used while the ventilation unit is turned on.

Filter Module
Cat. # $/Each
Filter Module 1685-82 Login
Exhaust Purification Filter (activated charcoal)
1716-00A Login
HEPA Filter
(99.99% efficient @ 0.3µm)
1681-02 Login
ULPA Filter
(99.999% efficient @ 0.12µm)
1681-10 Login
The stainless steel housing accommodates a charcoal purification filter and a HEPA or ULPA final particle filter
 
Blower Module
Cat. # $/Each
110VAC, 60Hz
1685-83 Login
220VAC, 50Hz 1685-83-220 Login
The stainless steel housing encloses a 740 CFM variable-speed impeller that draws fumes upwards. One-piece gasket ensures leak-tight performance. Price includes installation on specified Series 200 chamber.

Iris Ports
See above


More Products
 

Top of Page

714-578-6000

All prices and specifications are subject to change without notice. Crating charges apply to selected items.
Call or click here for more information on terms and conditions.

© 1998-2007 Terra Universal, Inc. All rights reserved.